NICEIC Approved Contractor Sidcup, Kent · Serving London & the South East
[email protected] Mon–Fri 8:00–17:30 020 8859 7512

Electrical Compliance

NICEIC-approved EICR testing, emergency lighting testing to BS 5266, witness testing, PAT and asset stewardship for industrial, commercial and public-sector organisations.

Electrical compliance

EICR testing and electrical compliance you can rely on

JKS are an NICEIC approved contractor that offers comprehensive electrical testing and asset stewardship programmes for organisations within the industrial, commercial and public sectors. By providing a high-quality testing service we can foresee any future problems ahead of time, potentially cutting your costs.

Electrical installations deteriorate with age, use and alteration. Connections loosen, insulation breaks down, circuits get extended and protective devices stop matching the loads they serve. Regular inspection and testing finds these issues while they are still cheap to fix — before they cause a fire, an electric shock or an unplanned shutdown.

We combine thorough testing with clear reporting and practical recommendations, so you know exactly where you stand and what to do next.

Request a quotation
JKS London engineer carrying out electrical inspection and testing

Our compliance services

Electrical testing services for industrial, commercial and public-sector sites

EICR / periodic fixed wire testing

Inspection and testing of your fixed installation to BS 7671, recorded on an Electrical Installation Condition Report with clearly coded observations.

Emergency lighting testing

Monthly functional and annual full-duration testing to BS 5266, with log book records, certification and repairs to failed fittings.

Witness testing & consultancy

Independent witnessing of tests on new or altered installations, with reports and advice on compliance with BS 7671.

Asset stewardship

Asset registers, schematic production and change-control procedural support so you always know what is installed and how it is protected.

PAT testing

Risk-based in-service inspection and testing of portable and transportable equipment in line with the IET Code of Practice.

Thermal imaging

Thermographic surveys that detect overheating connections and overloaded components without switching off.

Why it matters

Why regular electrical testing protects your organisation

Electrical compliance is not just paperwork. It protects people, keeps your premises trading and gives you evidence when insurers, auditors or enforcing authorities ask for it.

Meet your legal duties

Employers and those in control of premises must maintain electrical systems to prevent danger. A current EICR is your strongest evidence.

Reduce fire risk

Overloaded circuits, loose terminations and damaged cables are common ignition sources. Testing finds them early.

Satisfy insurers and landlords

Insurance policies, leases and fire risk assessments frequently require up-to-date electrical certification.

Control costs

Planned remedial work is cheaper than emergency repairs, lost trading and damaged stock after a failure.

Periodic inspection

EICR testing in London & Kent

An Electrical Installation Condition Report (EICR) is the formal record of a periodic inspection and test of your fixed wiring — distribution boards, cables, sockets, lighting circuits, fixed equipment and earthing and bonding arrangements. It is the main way duty holders show they are meeting the requirement of the Electricity at Work Regulations 1989 to maintain electrical systems so as to prevent danger.

Our NICEIC-qualified inspectors test to the current edition of BS 7671, recording any departures as C1 (danger present), C2 (potentially dangerous), C3 (improvement recommended) or FI (further investigation required). The overall result is either satisfactory or unsatisfactory.

Read our guides to EICRs for commercial properties and understanding EICR codes for more detail.

Commercial distribution board being inspected during an EICR

How often?

Typical EICR inspection intervals by premises type

The IET’s Guidance Note 3: Inspection & Testing sets out recommended maximum periods between periodic inspections. Common examples include:

Type of premisesRecommended maximum interval
Offices, shops and general commercial premises5 years (or change of occupancy)
Restaurants and hotels5 years
Educational establishments5 years
Hospitals5 years
Residential accommodation (e.g. care homes, HMOs)5 years
Domestic, privately rented (England)5 years — required by the Electrical Safety Standards in the Private Rented Sector Regulations 2020
Industrial premises3 years
Leisure complexes, theatres and places of public entertainment3 years
Agricultural and horticultural premises3 years
Swimming pools, petrol filling stations and marinas1 year
Construction site installations3 months

Note: These are maximum intervals, not targets. The inspector will recommend a shorter period where the installation is old, heavily used, in a harsh environment or showing signs of deterioration — commercial kitchens are a common example. Insurers and leases may also set their own requirements.

Want a ballpark figure before you request a quote? Use our EICR cost calculator.

Beyond the EICR

Emergency lighting, witness testing and asset stewardship

Illuminated emergency exit sign

Emergency lighting tests to BS 5266

Emergency escape lighting must work the moment the mains supply fails. BS 5266-1 recommends a brief monthly functional test of every luminaire and sign, and an annual test for the full rated duration — typically three hours. We carry out both, record results in your log book, replace failed batteries and lamps and issue certification. See our guide to emergency lighting testing duties.

Book emergency lighting testing
Engineer witnessing electrical test results

Witness testing reports & consultancy to BS 7671

When another contractor completes new installation work, you need confidence that the tests were done properly and the results comply. We independently witness testing, review certification and schedules of test results, and report on compliance with BS 7671 — giving clients, landlords and project teams an impartial view before handover.

Discuss witness testing
Cable tray and containment in a plant area

Asset stewardship

Many buildings lack accurate records of what is installed. We build and maintain electrical asset registers, produce schematics and distribution board schedules, and provide change-control procedural support so alterations are planned, recorded and reflected in your drawings. Good records make testing faster and future works safer.

Asset management within FM
Portable appliance being PAT tested

PAT testing

Portable equipment such as kettles, kitchen appliances, IT equipment and power tools must also be maintained. We take a risk-based approach to frequencies in line with the IET Code of Practice for In-service Inspection and Testing, label equipment and provide a full register. Read PAT testing explained.

Book PAT testing

What’s included

What every inspection includes

  • Pre-visit planning: scope, access, isolation sequence and any permit requirements
  • Visual inspection of accessible wiring, accessories, enclosures and equipment
  • Dead and live testing of a representative sample of circuits, agreed in advance
  • Checks on earthing, bonding and the operation of RCDs and protective devices
  • Identification of damage, overloading, unsuitable alterations and wear
  • Safe reinstatement of supplies and a clear on-site debrief

Deliverables

What you receive

  • Electrical Installation Condition Report issued through our NICEIC registration
  • Schedules of inspections and test results for every circuit tested
  • Observations coded C1, C2, C3 or FI with plain-English explanations
  • A prioritised remedial quotation for any defects found
  • Updated circuit charts and, where agreed, asset registers and schematics
  • A recommended date for the next inspection

Key clients

Trusted by national and public-sector organisations

Our electrical compliance clients have included The Restaurant Group, Public Health England, Bison Concrete and Furniture Hire UK — organisations with very different installations, from busy restaurant kitchens to laboratories, industrial sites and warehouses. Each needed reliable testing, clear reports and minimal disruption to their operation.

View case studies

Our process

How an electrical compliance programme works

  1. Review

    We review your existing certificates, drawings and asset information and agree the scope and sample size.

  2. Plan

    Testing is scheduled around your operation, with isolations agreed in advance and out-of-hours working where needed.

  3. Test & inspect

    Our engineers carry out the inspection and testing safely, keeping your on-site team informed throughout.

  4. Report

    You receive your certificates and a prioritised action plan, with urgent dangers made safe or reported immediately.

  5. Remedy & re-certify

    We complete agreed remedial works and issue the appropriate certification.

  6. Schedule

    Re-test dates are diarised so your compliance programme keeps running without you having to chase it.

Book online

Fixed-price compliance packages

Commercial EICR

Periodic inspection and testing with full certification.

View package

Emergency lighting

Testing and certification to BS 5266.

View package

PAT testing

In-service inspection, testing and labelling.

View package

Thermal imaging

Non-intrusive survey of boards and switchgear.

View package

Tip: Combining your EICR, emergency lighting test and PAT testing into one visit reduces disruption and repeat call-out costs. Learn more about thermal imaging surveys as a complement to periodic testing.

FAQ

Frequently asked questions

How often does a commercial property need an EICR?

IET Guidance Note 3 recommends a maximum interval of five years for most commercial premises such as offices, shops, restaurants and hotels, with shorter intervals for industrial sites, leisure facilities and special locations. The inspector may recommend a shorter interval based on the condition and use of the installation.

Is an EICR a legal requirement for businesses?

The Electricity at Work Regulations 1989 require electrical systems to be maintained so as to prevent danger. Periodic inspection and testing, recorded on an EICR, is the recognised way to demonstrate that duty is being met, and insurers and landlords commonly require it.

Will testing disrupt my business?

Testing requires circuits to be isolated for short periods. We plan the sequence with you and can work early mornings, evenings or weekends to keep critical areas such as kitchens, tills and IT running.

What happens if my EICR is unsatisfactory?

An unsatisfactory result means at least one C1, C2 or FI observation was recorded. We explain each item, provide a prioritised quotation for remedial work and issue the appropriate certification once the work is complete.

How often should emergency lighting be tested?

BS 5266-1 recommends a short functional test every month and a full rated-duration test every year, with results recorded in a log book.

Do you provide PAT testing as well as fixed wire testing?

Yes. We carry out risk-based in-service inspection and testing of portable equipment in line with the IET Code of Practice, and can combine it with your EICR visit.

Arrange a free, no-obligation site visit

Tell us about your building and compliance needs — our team will get back to you within one working day.

Free, no-obligation site visit

Let's get started

Tell us what you need and we will come back to you within one working day.

    Preferred contact method

    * Required. We never share your details with third parties for marketing.

    Contact info

    AddressThe Stables, Unit 10
    Bunkers Hill
    Sidcup, Kent
    DA14 5EX
    Office hoursMon–Fri 8:00–17:30

    Accreditation

    Accreditation logo
    Call now Get a quote